Figure 16: Account read screen- meter information
Meter Information
Reading display
field
The meter reading displays in this field. In manual and touch reading mode, the field is blank until
the meter reader manually enters the reading or performs a touch read. In Auto mode, the field fills
automatically when a read is received for accounts with an ORION endpoint.
Data entry
direction
Tapping the arrow to the right of the field reverses the data entry direction when typing in a manual
reading. Gas meters readings are often entered from right to left in the reading field.
ORION ME Details This button displays only for ORION ME and SE (in mobile mode) endpoints. The button is red
when the reading has not yet been received from the endpoint and/or work items, requested in
ReadCenter Analytics or Analytics Mobile, are not completed. The button turns green when the
reading is received and work items, if any, have been completed.
Tap the button to view available two-way communication functions. For additional information,
refer to "ORION ME Details" onpage21.
Meter type The meter technology type displays to the right of the read field. In Figure 16 , the meter type is
ORION ME.
NOT: N If a valid COM port is not set, the meter technology type does not display.
Service number The service number displays below the meter type. The number changes to designate more than
one meter for an account such as an apartment building with multiple meters.
Alert Exception conditions such as High, Low or No Usage display in the blank field below the service
number as an alert. This field is blank when no alert is present.
NOT: N If there is a tamper condition, the word "TAMPER" displays in the reading display field.
Reading
display field
ORION ME details
Data entry direction
Meter type
Service number
Alert field
ORION® Automated Meter Reading System for Trimble® Ranger 3